Provision Of Isolation Switch For Starring Battery In Power Car As Per Rdso Modification Sheet No. Rdso/Pe/Ms/Ac/0086-2022 (Rev.0) Or Latest. The Works Includes Supply, Installation, Testing And Commi Ssioning Of Isolation Disconnector Switch With Fuse Of Approved Make. List Of Material Required In 1 Set Pow Er Cars (1 Power Car Having 2 Nos. D.A. Set) In Above Modification :- 1. Switch Disconnecting Fuse (Sdf) 2 P Ole 315A, 415V Insulation Suitable For 690 Volt With 315A 415V Breaking Capacity Minimum 100Ka Rating Fu Se And Metallic Cover, The Switch Disconnector Of Make L&T (Ck910070009 ? Sf94234), Siemens (3Kx8345- 4Ac-3Kl8331-2Ua00-3Na33520Rc), Abb Or Schneider -02 Nos. 2. Copper Cable 120Sq.Mm. As Per Rdso S Pecification No. Elrs/ Spec/Elc/0019. (Rev.-1) - 32 Mtr. 3. Fuse Link Sf 94234 315A - 04 Nos. 4. Conduit As Per Rdso Specification Rdso/Pe/Spec/Ac-0138 2009 (Rev1) For 120 Sq.Mm. Copper Cable (Nw-29) - 32 Mtr . 5. Cable Glands - 08 Nos(Pg29) & 02 Nos (Pg 16). 6. Control Cable Length - 50 Mtr. 7. Heavy Duty Copper Tubular Crimping Socket For E Beam Cable Of Size 120Sq.Mm. Stud Size Size M 16 To Item No.20 Of Rcf Specif Ication No.Edts-200-08 Nos. Note- Supplier To Be Produce Oem Dealership Certificate Or Authorization Of Oe M. [ Warranty Period: 30 Months After The Date Of Delivery ] ]